Easy to use. Designed to be user-friendly with intuitive controls and a straightforward workflow, making it easy to capture high-quality images quickly and efficiently. An excellent system to start learning microscopy — best suited for internship students.

Routine work. The Zeiss Axio Imager M2 is designed for routine work on fixed samples, making it an ideal tool for any research lab doing microscopy imaging experiments.

Multiple imaging modes. The microscope can perform Brightfield, DIC, and Epi-fluorescence imaging, giving you the flexibility to choose the imaging mode that best suits your needs.

High-quality imaging. Capable of producing high-quality images with excellent contrast and resolution thanks to its advanced imaging technology and the ApoTome feature.

ApoTome. Structured illumination enables optical sectioning of fixed samples, producing confocal-like images on thin samples at a much lower cost than a confocal microscope.

Zeiss Apotome Axio Imager M2
At a Glance
  • Stand: Zeiss Axio Imager M2 · Upright
  • Camera: Hamamatsu ORCA Flash 4.0 LT · 4 MP · 16-bit
  • Illumination: X-Cite 120 LED Boost
  • Filter sets: DAPI · eGFP · mCherry · Cy5
  • Optical sectioning: ApoTome 2
  • Objectives: 10× · 20× · 40× dry · 40× oil · 63× oil
  • Incubation: None

Hardware
System Specifications
  • Zeiss AxioImager M2 (ref: 430004-9902-000)
  • Upright stand
  • Z-drive motorized basic · step size 25 nm
  • Motorized 6-position objective revolver (ref: 424505-0000-000)
  • Motorized 6-position reflector turret (ref: 424907-0000-000)
  • ref: 410830-1768-000 · Cat: C11440-42U30
  • Manufacturer: Hamamatsu Photonics K.K.
  • Sensor: Scientific CMOS
  • Sensor size: 18.8 mm (13.312 × 13.312 mm)
  • Resolution: 2048 × 2048 px (4 MP)
  • Pixel size: 6.5 × 6.5 µm
  • Bit depth: 16 bit/pixel
  • Exposure range: 3 ms – 10 s
  • Binning: 1×1, 2×2, 4×4
  • Frame rate: 30 fps (2048×2048)
  • Quantum efficiency: 82% at 560 nm
  • Fluorescence: X-Cite 120 LED Boost (ref: 410842-2098-000 · Excelitas cat. XT120L)
  • Transmitted: Illuminator VIS-LED (ref: 423053-9030-000)
  • Eyepieces: PL 10×/23 Br.Foc.Pl (ref: 444036-9000-000)
  • Mechanical stage 75×50/240°R (ref: 432001-9902-000)
  • Specimen holder 76×26, one-hand operation for immersion (ref: 432308-0000-000)
  • Universal condenser achromatic-aplanatic 0.9 H D Ph DIC mot. (ref: 424201-9903-000)
  • NA: 0.9 · WD: 1.2 mm · 6 positions: H, Ph1, Ph2, Ph3, DIC, DIC
  • Motorized front lens, aperture diaphragm and turret disk
  • Analyzer module DIC ACR P&C shift-free (ref: 424932-9901-000)
  • DIC slider EC PN 10×/0.30 I · 20×/0.50 II · PA 20×/0.80 II (ref: 426940-0000-000)
  • DIC slider EC PN & Fluar 40×/1.30 III · PA 40×/0.95 III (ref: 426944-0000-000)
  • DIC slider PA 63×/1.40 III (ref: 426957-0000-000)
  • Optical sectioning: ApoTome 2 for Axio Imager (ref: 423667-9100-000)
  • Reflector module FL EC P&C (ref: 424931-0000-000)
  • Workstation Z840 (ref: 410902-9901-000)
  • Intel Xeon CPU E5-2623 v3 @ 3.00 GHz · 32 GB RAM
  • Windows 10 Pro · LCD TFT 24″ z24n monitor
  • ZEN Pro 3.1
  • Modules: Z-stack · Hamamatsu camera driver

Optics
Objectives
Objective NA Immersion Coverslip Working Distance Field of View DIC Slider
EC Plan-Neofluar 10×/0.3 M27 (ref: 420340-9901-000) 0.3 Dry 0.17 mm 5.2 mm 25 mm EC PN 10×/0.30 I
Plan-Apochromat 20×/0.8 M27 (ref: 420650-9901-000) 0.8 Dry 0.17 mm 0.55 mm 25 mm EC PA 20×/0.80 II
EC Plan-Neofluar 40×/0.75 M27 (ref: 420360-9900-000) 0.75 Dry 0.17 mm 0.71 mm 25 mm None
EC Plan-Neofluar 40×/1.30 Oil M27 (ref: 420460-9900-000) 1.30 Oil 0.17 mm 0.21 mm 25 mm EC PN 40×/1.30 III
Plan-Apochromat 63×/1.4 Oil DIC M27 (ref: 420782-9900-000) 1.4 Oil 0.17 mm 0.19 mm 25 mm PA 63×/1.40 III

Fluorescence
Filter Sets & Spectra Viewer
DAPI Ex ~365 nm · Em ~445 nm
eGFP Ex ~470 nm · Em ~525 nm
mCherry Ex ~572 nm · Em ~629 nm
Cy5 Ex ~640 nm · Em ~690 nm