Cutting-edge confocal with spectral detection. The Zeiss LSM 980 is optimized for spectral detection of multiple weak labels with the highest light efficiency, thanks to its QUASAR 34-channel detectors and optimized beam path. This means even the faintest signals can be imaged with the highest sensitivity.
Airyscan 2 super-resolution. The Airyscan 2 module is an area detector with 32 concentrically arranged detection elements that collect more photons for greater light efficiency. This results in exceptional super-resolution imaging that is gentle and sensitive, with a maximum resolution of 120/120 nm in Super Resolution mode.
Multi-photon microscopy. Capable of imaging deep into live or fixed samples. With efficient capture of emission light using non-descanned, QUASAR, or Airyscan detectors, deep tissue penetration is combined with increased sensitivity, resolution, and speed.
Expand your imaging capabilities. Access more details and data from your sample, faster and with higher productivity and image quality. The flexible and sensitive system will help you achieve new insights and discoveries in your research.
- Stand: Zeiss Axio Examiner Z1 · Upright
- Lasers: 405 · 488 · 514 · 561 · 594 · 639 nm + Chameleon MP (690–1040 nm)
- Detectors: QUASAR 34-ch · Airyscan 2 · GaAsP PMT · T-PMT
- Super-resolution: Airyscan 2 · 120/120 nm
- Objectives: 10× · 20× dry · 20× water · 40× water · 63× oil
- Stage: Motorized + Z-piezo 130×85 mm
- Incubation: Temperature (Pecon)
- Zeiss Axio Examiner Z1 (ref: 409000-9752-000)
- Upright stand
- Motorized objective focusing · 25 nm increment
- 6-position filter turret
- Docking station for TFT display
- 2× 10×/23 eyepieces
- Transmitted illumination: Halogen lamp 12V 100W (ref: 380059-1660-000)
- Lamphousing 12V/100W with collector (ref: 423000-9901-000)
- Widefield fluorescence: Illuminator HXP 120 V · Metal halide (ref: 423013-9010-000)
- Reflector module FL EC P&C (ref: 424931-0000-000)
- 405 nm — Diode
- 488 nm — Diode
- 514 nm — Diode
- 561 nm — DPSS
- 594 nm — DPSS
- 639 nm — Diode
- Chameleon Vision II — 690 nm to 1040 nm (multi-photon)
- Spectral detector QUASAR: 32 channels GaAsP PMT + 2 channels MA-PMT (ref: 000000-2224-559)
- Big.2 Type A GaAsP PMT (ref: 000000-2183-174)
- Airyscan 2 (ref: 000000-2183-168)
- T-PMT (ref: 000000-2183-233)
- Filter set Blue & Green (ref: 000000-1935-174)
- Filter set Green & Red (ref: 000000-1935-176)
- Dichroic BS MP UV/690 (ref: 447962-9001-000)
- Dichroic mirror BS-MP 760 (ref: 000000-1989-686)
- LBF 355/690 (ref: 000000-1785-479)
- Shortpass IR blocking filter LBF760+ with handle (ref: 000000-1989-670)
- 32 concentrically arranged GaAsP detection elements
- BP 420-475 nm + BP 500-545 (ref: 0000000-2070-487)
- BP 420-480 nm + BP 570-630 (ref: 0000000-2284-690)
- BP 420-500 nm + LP 605 (ref: 0000000-2284-693)
- BP 465-505 nm + BP 525-585 (ref: 0000000-2287-628)
- BP 495-560 nm + LP 660 (ref: 0000000-2284-692)
- BP 570-620 nm + LP 655 (ref: 0000000-2183-190)
- Scanning stage 130×85 mm Piezo (ref: 432022-9903-000)
- Mounting frame 160×116 for slides 76×26 (ref: 432315-0000-000)
- Adjustable insert scanning stage imager (ref: 410800-1000-000)
- Z-piezo stage insert WSB 500 (ref: 000000-2248-929)
- Stage insert Z piezo for specimen slides 76×26 (ref: 432339-9060-000)
- Stage insert Z piezo for Petri dishes 25–86 mm (ref: 432339-9070-000)
- Stage controller XY Piezo WSB CAN (ref: 432901-9904-000)
- Incubation (Pecon): Incubator XL S1 dark (ref: 411857-9431-000)
- Temp Module S1 (ref: 411860-9010-000)
- Heating unit XL S2 (ref: 411857-9031-000)
- LED lamp (ref: 411857-9600-000)
- HP Z6 G4 workstation (ref: 410203-9911-000)
- Intel Xeon Gold 6134 · 192 GB RAM · SSD 512 GB · HDD 8 TB SATA 7200 rpm
- NVIDIA Quadro P6000 · Monitor TFT 32″ HP Z32 · Windows 10
- ZEN Pro 3.1 (ref: 410135-1003-310)
- Modules: Measurement · Multi-channel · Panorama · Manual extended focus · Image analysis · Time-lapse · Z-stack · Extended focus · Autofocus · Colocalisation · Spectral unmixing · 3Dxl · Deconvolution · FRAP/FRET · Experiment designer · Tiles/Positions · RICS · Counting · Direct processing
| Objective | NA | Immersion | Coverslip | Working Distance | Field of View | DIC Slider |
|---|---|---|---|---|---|---|
| Plan-Apochromat 10×/0.45 (ref: 420640-9900-000) | 0.45 | Dry | None | 2.1 mm | — | PA 10×/0.45 II |
| Plan-Apochromat 20×/0.8 (ref: 420650-9902-000) | 0.8 | Dry | 0.17 mm | 0.55 mm | — | EC PN 10× 20× / PA 20× |
| W Plan-Apochromat 20×/1.0 (ref: 421452-9800-000) | 1.0 | Water | None | 1.80 mm | — | W PA 20×/1.0 III 75 Senarmont |
| W Plan-Apochromat 40×/1.0 (ref: 421462-9900-799) | 1.0 | Water | None | 2.5 mm | — | W PA 40×/1.0 III |
| Plan-Apochromat 63×/1.4 Oil (ref: 420782-9900-799) | 1.4 | Oil | 0.17 mm | 0.19 mm | — | None |
- Polarizer Senarmont DIC VIS/IR (ref: 427710-9030-000)
- Analyzer module Pol ACR P&C for transmitted light — installs in Epi Fluor Turret (ref: 424937-9901-000)
- DIC prism II/0.9 (ref: 426724-9070-000)
- DIC prism III/0.9 (ref: 426724-9080-000)
- DIC Slider PA 10×/0.45 II (ref: 000000-1045-073)
- DIC Slider EC PN 10× 20× / PA 20× (ref: 426940-0000-000)
- DIC Slider W PA 20×/1.0 III 75 Senarmont (ref: 426967-90000-000)
- DIC Slider W PA 40×/1.0 III (ref: 426967-9010-000)
- Condenser, achromatic-aplanatic (ref: 424226-9010-000)